Cable support falls off crane to an occupied deck below

What happened - icon

What happened?

While performing crane lifts, a cable support (wire rope wear board), measuring 20 inches in length, 4 inches in width, and 2 inches in thickness, and weighing ~8 lbs (3.7kg) fell ~35 feet (11metres) to deck below where workers were present.

Position of worker near the dropped object
What happened - icon

Why did it happen?

Carbon steel bolts securing the cable support (wear board) to the crane boom were found corroded and had failed.

Inspections of the cable support (wear board) securing bolts were not covered in the crane inspection strategy and preventative maintenance task lists.

Corroded equipment
What happened - icon

What did they learn?

Review the bolts securing cable supports (wear boards) and other ancillary equipment to crane booms.

Uncoated carbon steel bolts should be replaced with bolts of the correct capacity and with corrosion resistance that is suitable for the operating environment.

Verify that crane inspection strategies and preventative maintenance task lists include a physical and visual inspection of cable supports (wear boards) bolts and bolts supporting other ancillary crane equipment with dropped/fallen object potential.

Pre-use inspections should be performed by a qualified crane operator or qualified inspector and should include (but should not be limited to) performing a walk-around visual examination of the crane boom and support structure to verify that no visible damage exists.

Always ensure compliance with industry standards and best practices.

Cable support – each support is held in place by two bolts
What happened - icon

Ask yourself or your crew

  • What systems or measures do we have in place to prevent a similar situation taking place here?
  • What could be making us susceptible to experiencing an event like this?
  • How often do we inspect cable supports on our site, who is responsible for doing this and how is it documented?
  • What tasks are included in our preventative maintenance schedules, and when are they due for revision or updating?
  • What happened?

    While performing crane lifts, a cable support (wire rope wear board), measuring 20 inches in length, 4 inches in width, and 2 inches in thickness, and weighing ~8 lbs (3.7kg) fell ~35 feet (11metres) to deck below where workers were present.

    Position of worker near the dropped object
  • Why did it happen?

    Carbon steel bolts securing the cable support (wear board) to the crane boom were found corroded and had failed.

    Inspections of the cable support (wear board) securing bolts were not covered in the crane inspection strategy and preventative maintenance task lists.

    Corroded equipment
  • What did they learn?

    Review the bolts securing cable supports (wear boards) and other ancillary equipment to crane booms.

    Uncoated carbon steel bolts should be replaced with bolts of the correct capacity and with corrosion resistance that is suitable for the operating environment.

    Verify that crane inspection strategies and preventative maintenance task lists include a physical and visual inspection of cable supports (wear boards) bolts and bolts supporting other ancillary crane equipment with dropped/fallen object potential.

    Pre-use inspections should be performed by a qualified crane operator or qualified inspector and should include (but should not be limited to) performing a walk-around visual examination of the crane boom and support structure to verify that no visible damage exists.

    Always ensure compliance with industry standards and best practices.

    Cable support – each support is held in place by two bolts
  • Ask yourself or your crew

    • What systems or measures do we have in place to prevent a similar situation taking place here?
    • What could be making us susceptible to experiencing an event like this?
    • How often do we inspect cable supports on our site, who is responsible for doing this and how is it documented?
    • What tasks are included in our preventative maintenance schedules, and when are they due for revision or updating?